France – Prothèses vasculaires – Fourniture d’ « ENDOPROTHESES VASCULAIRES PERIPHERIQUES ET DISPOSITIFS MEDICAUX CONSOMMABLES
AI summary
This tender concerns the supply of peripheral vascular endoprotheses and consumable medical devices for AP-HP hospitals in France. The scope includes arterial endoprotheses, aortic dissection and aneurysm devices, carotid stents, lower limb endoprotheses, heparinized and venous stents, vena cava filters, embolectomy balloons, difficult vascular access systems, and arterial closure devices.
Medical device manufacturers or specialized distributors with proven expertise in vascular interventional products and established relationships with healthcare institutions should bid.
Suppliers must be qualified manufacturers or authorized distributors of vascular endoprotheses and medical devices meeting EU regulatory standards. CE marking and compliance with medical device directives are required. Experience in hospital supply and quality assurance systems are essential.
Frequently asked questions
What is this tender about?
This tender concerns the supply of peripheral vascular endoprotheses and consumable medical devices for AP-HP hospitals in France. The scope includes arterial endoprotheses, aortic dissection and aneurysm devices, carotid stents, lower limb endoprotheses, heparinized and venous stents, vena cava filters, embolectomy balloons, difficult vascular access systems, and arterial closure devices.
What are the requirements for suppliers?
Suppliers must be qualified manufacturers or authorized distributors of vascular endoprotheses and medical devices meeting EU regulatory standards. CE marking and compliance with medical device directives are required. Experience in hospital supply and quality assurance systems are essential.
What type of company should bid?
Medical device manufacturers or specialized distributors with proven expertise in vascular interventional products and established relationships with healthcare institutions should bid.
Who is the buyer?
The buyer is AGEPS APHP.
When does this tender close?
Submissions close on September 4, 2026.
What is the estimated value?
The estimated value is 67,380,419 EUR.
Fourniture d’ « ENDOPROTHESES VASCULAIRES PERIPHERIQUES ET DISPOSITIFS MEDICAUX CONSOMMABLES : endoprothèses vasculaires périphériques artérielles, endoprothèses pour dissection et anévrismes de l’aorte et consommables associés, endoprothèses vasculaires et shunts carotidiens, endoprothèses des membres inférieurs, endoprothèses héparinées, veineuses et biliaires, filtres veine cave, ballons d’embolectomie et ballons d’occlusion, systèmes d'accès vasculaire difficile, systèmes de fermeture artérielle »
Fourniture d’ « ENDOPROTHESES VASCULAIRES PERIPHERIQUES ET DISPOSITIFS MEDICAUX CONSOMMABLES
Descriptif des lots 1 à 27 : LOT 1 Endoprothèse vasculaire périphérique en alliage à base de chrome-cobalt, expansible par ballon, pré sertie, non couverte, compatible avec un guide 0,014'', de diamètre ≥ 4 mm "QUANTITES ANNUELLES INDICATIVES " 100 CIRCUIT DIRECT ; LOT 2 (=3) Endoprothèse vasculaire périphérique en alliage à base de chrome-cobalt, expansible par ballon, pré sertie, non couverte, compatible avec un guide 0,035'' "QUANTITES ANNUELLES INDICATIVES " 150 CIRCUIT DIRECT ; LOT 3 (=2) Endoprothèse vasculaire périphérique en alliage à base de chrome-cobalt, expansible par ballon, pré sertie, non couverte, compatible avec un guide 0,035'' "QUANTITES ANNUELLES INDICATIVES " 150 CIRCUIT DIRECT ; LOT 4 Endoprothèse vasculaire périphérique en alliage à base de chrome-cobalt expansible par ballon, pré sertie, non couverte, de Diamètre > 12 mm "QUANTITES ANNUELLES INDICATIVES " 50 CIRCUIT DIRECT ; LOT 5 Endoprothèse vasculaire périphérique en alliage à base d’acier 316L,expansible par ballon, pré sertie, non couverte, compatibles avec un guide 0,018'' "QUANTITES ANNUELLES INDICATIVES " 30 CIRCUIT DIRECT ; LOT 6 Endoprothèse vasculaire périphérique en alliage à base d’acier 316L, expansible par ballon, pré sertie, non couverte, compatible avec un guide de 0,035'' avec système de pose co-axial "QUANTITES ANNUELLES INDICATIVES " 50 CIRCUIT DIRECT ; LOT 7 (=8) Endoprothèse vasculaire périphérique en alliage à base d’acier 316L, expansible par ballon, pré sertie, couverte "QUANTITES ANNUELLES INDICATIVES " 500 CIRCUIT DIRECT ; LOT 8 (=7) Endoprothèse vasculaire périphérique en alliage à base d’acier 316L, expansible par ballon, pré sertie, couverte "QUANTITES ANNUELLES INDICATIVES " 200 CIRCUIT DIRECT ; LOT 9 Endoprothèse vasculaire périphérique en alliage à base d’acier 316L, expansible par ballon, pré sertie, couverte, héparinée, compatible fil guide 0,035", Compatible introducteur 6, 7, 8F "QUANTITES ANNUELLES INDICATIVES " 100 CIRCUIT DIRECT ; LOT 10 (=11) Endoprothèses vasculaires périphériques en alliage à base de chrome-cobalt, expansible par ballon, pré sertie, couverte "QUANTITES ANNUELLES INDICATIVES " 1 050 CIRCUIT DIRECT ; LOT 11 (=10) Endoprothèses vasculaires périphériques en alliage à base de chrome-cobalt, expansible par ballon, pré sertie, couverte "QUANTITES ANNUELLES INDICATIVES " 350 CIRCUIT DIRECT ; LOT 12 "Endoprothèses vasculaires périphériques en alliage à base de chrome-cobalt, de type ""stent de pontage"", explansible sur ballon - couvert de PTFE - diamètre dégressif " "QUANTITES ANNUELLES INDICATIVES " 50 CIRCUIT DIRECT ; LOT 13 Endoprothèse vasculaire périphérique en alliage à base de chrome-cobalt, expansible par ballon, pré sertie, couverte de PTFE, de diamètre > 12 mm "QUANTITES ANNUELLES INDICATIVES " 50 ; LOT 14 Endoprothèse vasculaire périphérique en nitinol, auto-expansible, couverte "QUANTITES ANNUELLES INDICATIVES " 160 CIRCUIT DIRECT ; LOT 15 Endoprothèses vasculaires périphérique autre matériau que nitinol, auto-expansible, non couverte "QUANTITES ANNUELLES INDICATIVES " 50 ; LOT 16 Endoprothèse vasculaire périphérique en nitinol, auto-expansible, non couverte, compatibles avec un introducteur de 5-6-7 F "QUANTITES ANNUELLES INDICATIVES " 50 ; LOT 17 Endoprothèse vasculaire périphérique en nitinol, auto-expansible, non couverte, compatible avec un introducteur de 4 F "QUANTITES ANNUELLES INDICATIVES " 30 ; LOT 18 Endoprothèse vasculaire périphérique en nitinol, auto-expansible, non couverte, de gros diamètre (> 15 mm) "QUANTITES ANNUELLES INDICATIVES " 50 ; LOT 19 Endoprothèse vasculaire périphérique en nitinol, auto-expansible, non couverte, compatible avec un guide de 0,018’’ "QUANTITES ANNUELLES INDICATIVES " 120 ; LOT 20 (=21) Endoprothèse vasculaire périphérique en nitinol, auto-expansible, non couverte, compatible avec un guide de 0,035’’ avec système de pose co-axial "QUANTITES ANNUELLES INDICATIVES " 1 000 ; LOT 21 (=20) Endoprothèse vasculaire périphérique en nitinol, auto-expansible, non couverte, compatible avec un guide de 0,035’’ avec système de pose co-axial "QUANTITES ANNUELLES INDICATIVES " 300 ; LOT 22 Endoprothèse vasculaire périphérique en nitinol, auto-expansible, non couverte, compatible avec un guide de 0,014" et/ou 0,018’’, avec système de pose co-axial, avec maillage ultra-flexible tressé "QUANTITES ANNUELLES INDICATIVES " 100 ; LOT 23 Endoprothèse vasculaire périphérique en nitinol, autoexpansible à élution de principe actif "paclitaxel" "QUANTITES ANNUELLES INDICATIVES " 200 CIRCUIT DIRECT ; LOT 24 Endoprothèse vasculaire périphérique en nitinol de type, autoexpansible, à élution de principe actif de type "limus" "QUANTITES ANNUELLES INDICATIVES " 100 CIRCUIT DIRECT ; LOT 25 Endoprothèse vasculaire périphérique résorbable, expansible sur ballon, à élution de principe actif de type "limus" "QUANTITES ANNUELLES INDICATIVES " 100 CIRCUIT DIRECT ; LOT 26 (=27) Cathéter à ballonnet pour angioplastie périphérique à élution de principe actif paclitaxel de diamètre ≥ 4 mm "QUANTITES ANNUELLES INDICATIVES " 900 CIRCUIT DIRECT ; LOT 27 (=26) Cathéter à ballonnet pour angioplastie périphérique à élution de principe actif paclitaxel de diamètre ≥ 4 mm "QUANTITES ANNUELLES INDICATIVES " 450 CIRCUIT DIRECT ;
Scoring criteria not specified
Computing match…
AI document analysis
We read the tender PDFs and DOCX files and surface key requirements, deadlines, budget and red flags.
Loading…